Hydrone 5 Plant Dehumidifier by AC Infinity - precision VPD humidity control system
Hydrone 5 Plant Dehumidifier by AC Infinity - precision VPD humidity control system
Hydrone 5 Plant Dehumidifier by AC Infinity - precision VPD humidity control system
Hydrone 5 Plant Dehumidifier by AC Infinity - precision VPD humidity control system
Hydrone 5 Plant Dehumidifier by AC Infinity - precision VPD humidity control system
Hydrone 5 Plant Dehumidifier by AC Infinity - precision VPD humidity control system
Hydrone 5 Plant Dehumidifier by AC Infinity - precision VPD humidity control system
Hydrone 5 Plant Dehumidifier by AC Infinity - precision VPD humidity control system

Hydrone 5 Plant Dehumidifier by AC Infinity — 10-Level PWM Humidity & VPD Control

AC-DHT5

Regular price $385.00 Sale price$329.95 Save $55.05
/
Shipping calculated at checkout.

  • Low stock - 2 items left
  • Backordered, shipping soon
  • Free shipping on orders over $499*

The Hydrone 5 is a plant dehumidifier built for grow tents up to 4x4, rated by AC Infinity for four plants. Instead of a compressor thumping on and off, it runs a PWM rotary motor across ten distinct drying levels with instant response — so you hold a humidity target rather than swinging around it. Dual 6-inch duct ports let you send dry air exactly where it is needed or run a closed loop, and the onboard UIS port hands control to an AC Infinity smart controller for full VPD automation.

Sizing — worth a quick read AC Infinity rates the Hydrone 5 for grow tents up to 4x4 (120 x 120cm) with four plants. It will still do useful work in a 5x5, but expect it to be working harder and holding a looser target, especially with a full canopy in late flower. If you are sitting on that line, talk to us first and we will help you work out whether one unit gets you there.
PWM Rotary Motor, 10 Levels Ten distinct drying levels with instant on-off response. A compressor unit overshoots and cycles; this modulates, which is what keeps VPD steady rather than sawtoothing.
Works Hot and Cold Compressor dehumidifiers lose effectiveness as rooms get cold — a real problem in an unheated garage overnight. This design holds performance across both extremes.
Pulls Down to 25% RH Enough headroom for late flower and drying rooms, where holding low humidity is the difference between a clean finish and bud rot.
Dual 6-Inch Duct Ports Exhaust dry air straight into the canopy zone, or add intake ducting for a closed loop. Lets you park the unit outside the tent and reclaim the floor space.
Integrated UIS Port Plug into an AC Infinity smart controller for app access, humidity and VPD automation, data charts and alerts. Auto-memory restore keeps settings after a power cut.
Drainage Ready A 2L internal reservoir for casual use, or run the optional gravity drain hose to a floor drain or bucket and stop emptying it entirely.

Specifications

Model
HYDRONE 5 (AC-DHT5)
Coverage
Up to 4x4 grow tents (4 plants)
Engine
PWM rotary motor
Drying Levels
10
Real-World Draw Rate
4L (not directly comparable to compressor ratings)
Lowest RH
25% RH
Reservoir Capacity
2L (0.5 gallon), gravity drain optional
Ducting Ports
Dual 6 inch (15 cm)
Wattage
209 to 350 W
Voltage
240V AC, 50Hz (Australian model)
Smart Control
Integrated UIS port, auto-memory restore
Dimensions
24.2 x 26.0 x 39.8 cm
Warranty
2 Years (AC Infinity)
UPC
819137025202
Running it properly
  • Every dehumidifier adds heat as it works. In summer, park the unit outside the tent and duct the dry air in, or you will win on humidity and lose on temperature
  • Run the gravity drain if you are in late flower. A 2L reservoir fills faster than you think when the plants are transpiring hard, and a full tank means it stops working
  • Lower levels in veg, higher in late flower. Match drying output to plant mass rather than leaving it flat out all cycle
  • Closed-loop is more efficient but recirculates the unit's own heat. Open-loop with outside intake air runs cooler if your room allows it
  • Pair it with a controller and set VPD targets rather than raw RH. Humidity alone will not tell you what the plants are experiencing

Setting It Up

1
Decide inside or outside. Inside is simplest and keeps all the dry air in the tent. Outside with ducting keeps the waste heat out of your space — usually the better call from spring onward.
2
Duct the exhaust into the canopy zone. Standard 6-inch ducting fits the exhaust port. Aim the outlet where air is moving, not into a dead corner, so the dry air actually mixes through the tent.
3
Choose open or closed loop. Leave the intake port open to draw room air, or duct it back from the tent for a closed loop. Closed loop is more efficient; open loop runs cooler.
4
Sort out drainage before you switch on. Fit the gravity drain hose and run it to a drain or bucket below the unit. Gravity does the work, so the outlet has to sit lower than the port.
5
Set a level, or connect a controller. Manual mode: pick a drying level 1 to 10. Automated: plug the UIS port into an AC Infinity controller and set humidity or VPD targets in the app.
6
Watch the first 24 hours. Check your RH and temperature together. If humidity drops but temperature climbs past target, move the unit outside the tent or add extraction before you change anything else.

Pairs Well With

Frequently Asked Questions

Will the Hydrone 5 handle a 5x5 tent?

Yes, it has the potential to — but do not expect it to land you exactly where you want to be. AC Infinity rates the Hydrone 5 for tents up to 4x4 with four plants. Put it in a 5x5 and it will still pull humidity down and make a real difference, it just may not hold a tight target, particularly with a full canopy in late flower. If you are sitting on that line, talk to us and we will work out whether one unit gets you there or you are better off stepping up.

Is it better than a normal household dehumidifier?

Yes, for a grow room. Household compressor units cycle hard, overshoot the setpoint, and lose capacity badly in cold conditions. The PWM rotary motor gives ten modulated levels with instant response, which is what holds a steady VPD. It also ducts, which a floor-standing household unit does not.

Can it control humidity automatically?

Yes, with a controller. On its own the Hydrone 5 runs at whichever of the ten levels you set. Connect the integrated UIS port to an AC Infinity smart controller and it will adjust output automatically against humidity or VPD targets, with app access, data charts and alerts.

Do I have to keep emptying the reservoir?

No, if you set up the drain. The internal reservoir holds 2L, which fills quickly during heavy transpiration. Fit the gravity drain hose and route it to a drain or a bucket sitting below the unit and it runs continuously without intervention.

Can I run it outside the tent?

Yes, and often you should. The dual 6-inch ports let you duct dry air into the tent while the unit sits outside, which saves floor space and keeps the heat it generates out of your growing environment. Add intake ducting back from the tent if you want a closed loop.

Is ducting included?

No. Ducting is sold separately and you will want standard 6-inch to match the ports. Plan on one run for the exhaust as a minimum, plus a second if you are setting up closed loop. The gravity drain hose is supplied with the unit.

Hold your humidity, not just watch it.

Ten drying levels, dual ducting and UIS smart control, rated for 4x4 tents. Not sure it suits your room? Ask us first — we would rather size it right than take the sale.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.