Genuine Aqua Master Tools replacement pH and temperature electrode (AMT1001) for the P50 Pro and P50 Pro2 pens. Unscrew, swap, recalibrate. IP67 once fitted.


  • Handpicked by growers
  • Ships today
  • Real advice, real people
  • 5,000+ high yielding customers
  • 30-day returns*
  • Free shipping over $499*
  • Low stock - 2 items left
  • Backordered, shipping soon

A pH pen does not die all at once. The glass bulb slowly loses its response, readings start to drift, calibration takes longer to settle, and one day it will not hold a calibration at all. On most pens that means buying a new meter. On the Aqua Master Tools P50 Pro and P50 Pro2 it means unscrewing the sealing ring and fitting this genuine replacement electrode (part AMT1001). It is the same pH and temperature sensor the pen shipped with, it is IP67 waterproof once fitted, and the swap takes a couple of minutes without tools. It fits both generations of the P50 and nothing else in the Aqua Master range.

Soak it before you use it. Aqua Master ships this electrode dry, and dried salt around the glass is normal. Stand the new electrode in tap water for at least 12 hours before fitting it, then calibrate. Skip the soak and the first readings will wander.
Fits the P50 Pro and P50 Pro2Aqua Master makes one P50 electrode (AMT1001) and it fits both generations of the pen. If you own a P50, this is the part.
Less than half the price of a new penA worn bulb is the only part of a P50 that wears out. Replace the electrode and the meter body, display and batteries carry on as they were.
No tools, no solderingUnscrew the sealing ring at the base of the pen, pull the old electrode, seat the new one with the recess lined up, tighten the ring. Done.
IP67 once it is fittedThe rubber seal and sealing ring restore the pen's full waterproof rating, so it still floats and still survives a dunk in the reservoir.
pH and temperature in one sensorThe temperature sensor lives in the electrode too, so automatic temperature compensation comes back with the new part.
Genuine part, six-month warrantyAqua Master Tools warrants the electrode for six months. Third-party parts void the pen's warranty, so this is the only one worth fitting.

Specifications

Brand: Aqua Master Tools
Part number: AMT1001
Fits: P50 Pro and P50 Pro2 pH & Temp pens
Measures: pH and temperature
Sensor: Glass pH bulb with integrated temperature sensor
Waterproof rating: IP67 when fitted to the pen
Fitting: Tool-free, via the pen's sealing ring
Before first use: Soak in tap water for 12 hours, then calibrate
Calibration after fitting: 2-point auto, pH 7.00 then pH 4.01
Storage: Upright with KCl storage solution in the cap (Aqua Master's recommendation)
Warranty: 6 months on the electrode
EAN: 8785258333705

Grower's Tip

  • Before you buy, try a clean and recalibrate. A bulb coated in nutrient film reads slow and drifty exactly like a worn one. Ten minutes in electrode cleaner, a rinse, then fresh pH 7 and pH 4 buffers. If it calibrates and holds, you did not need a new electrode.
  • Signs it really is worn: calibration fails or will not settle, readings drift while the pen sits in a stable buffer, the response time has blown out to a minute or more, or the glass is visibly cracked or chipped.
  • Use fresh buffer solution for the first calibration on a new electrode. Old buffers that have been dipped a dozen times are contaminated and will calibrate the new sensor to a wrong number.
  • Never store a pH electrode in distilled or RO water. It pulls the ions out of the glass and shortens its life. Tap water is fine for the pre-use soak; KCl storage solution in the cap is best for day to day.
  • Rinse the electrode with water after every reading and put the cap back on. Dried nutrient salts on the glass are the main reason pH electrodes wear out early.
  • Do not plunge a cold electrode into hot liquid or the other way round. Sudden temperature swings can crack the glass bulb, and that is not covered by warranty.
  • Keep the old electrode's rubber seal if the new one looks different. Aqua Master's instructions have you check the seal is seated before tightening, and a mis-seated seal is how water gets into the pen.

How To Fit It

1Soak the new electrode in tap water for at least 12 hours. This dissolves the dried salts and activates the glass. Do this before you touch the pen.
2Turn the pen off, take the cap off and unscrew the sealing ring at the lower end of the meter.
3Pull the old electrode straight out. Gently. It is a push fit onto connector pins, not a thread.
4Line up the recess on the new electrode with the pen body and push it home so the connectors mate properly. Forcing it in the wrong way round damages the pins.
5Check the rubber seal is sitting flat, then screw the sealing ring back on tight. This is what gives you the IP67 rating back.
6Run the pen's 2-point calibration in fresh pH 7.00 then pH 4.01 buffer, as described in the manual. The pen is ready once it confirms the calibration.

Want to see it done first? Watch Aqua Master Tools' electrode replacement video on YouTube.

Pairs Well With

Frequently Asked Questions

Does this electrode fit the P50 Pro2 as well as the original P50 Pro?

Yes. Aqua Master Tools makes a single P50 electrode, part AMT1001, and lists it as the replacement for both the P50 Pro and the P50 Pro2. The Pro2 changed the display, batteries and firmware, not the electrode.

Will it fit the P110, P160 or E50 pens?

No. Each Aqua Master pen family has its own electrode and they are not interchangeable. The P160 Pro and Pro2 use the P160 electrode (AMT1019), the P110 uses AMT1014 and the E50 uses the E50 EC electrode. Check the model name printed on your pen before ordering.

How do I know the electrode is worn and not just dirty?

Clean it first. Soak the bulb in electrode cleaner, rinse, then calibrate in fresh pH 7 and pH 4 buffers. If the pen still will not calibrate, drifts while sitting in a stable buffer, or takes more than a minute to settle, the glass has had its day and this electrode is the fix.

Do I need any tools to replace it?

No. The sealing ring at the base of the pen unscrews by hand, the old electrode pulls straight out and the new one pushes in. Aqua Master's own instructions are seven steps and most of them are "check the seal" and "calibrate".

Does the pen need recalibrating after I fit the new electrode?

Yes, every time. The calibration stored in the pen belongs to the old electrode. Soak the new one for 12 hours, fit it, then run the 2-point calibration in pH 7.00 and pH 4.01 before you trust a single reading.

Why does the new electrode have white crust on it?

That is dried salt from the electrode's internal solution and Aqua Master says it is normal. The 12-hour soak in tap water dissolves it and rehydrates the glass. It is not a fault and it is not a sign the part is old.

Is the pen still waterproof with a replacement electrode?

Yes, provided the rubber seal is seated and the sealing ring is done up tight. Aqua Master rates the electrode IP67 when attached to the meter, the same as the pen out of the box.

How long should a P50 electrode last?

It depends on how it is treated, and Aqua Master does not publish a figure. Rinsed after every use, capped with storage solution and kept out of concentrated nutrients and pH adjusters, a pH electrode lasts a long time. Left dry on a bench with nutrient crust on the glass, it will not. The warranty on the electrode itself is six months.

Fix the pen, keep the pen

Genuine Aqua Master Tools P50 electrode, shipped from Tasmania. Free shipping over $499*.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Growers First, Retailers Second

Welcome to The Grow Guys

We built The Grow Guys from the soil up — well, coco and perlite. Before we sold gear, we bought it, ran it, and learned the hard way what's worth the money and what ends up in the shed. That's the filter everything on our shelves passes through. No sales scripts, no rebadged junk, no telling you what you want to hear. Just gear we'd run ourselves and advice from people who actually grow. Chasing higher yields, tighter flowers, or your first harvest? You're in the right place.

FAQs

Order by 2pm and it ships the same business day from Invermay, Tasmania.

Calculated at checkout by weight and destination. Free shipping over $499*.

Plain packaging, no branding. No one knows what's in your box.

30-day change-of-mind returns on unopened, unused products. A 10% restocking fee applies and return shipping is at your cost.

Call, email, or walk into the Invermay shop. You'll get a grower on the other end, not a script.

Unit 10/110 Gleadow Street, Invermay 7248. Mon–Fri 8:30am–5:30pm, Sat 9am–3pm.


Recently viewed