Treegers PAR Meter Extendable Wand — Telescoping Sensor Mount for PPFD Mapping
Treegers PAR Meter Extendable Wand — Telescoping Sensor Mount for PPFD Mapping
Treegers PAR Meter Extendable Wand — Telescoping Sensor Mount for PPFD Mapping
Treegers PAR Meter Extendable Wand — Telescoping Sensor Mount for PPFD Mapping

Treegers PAR Meter Extendable Wand — Telescoping Sensor Mount for PPFD Mapping

TRG-MON-WAND-75CM

Regular price $32.50 Sale price$27.49 Save $5.01
/
Shipping calculated at checkout.

  • In stock, ready to ship
  • Backordered, shipping soon
  • Free shipping on orders over $499*

If you've used a PAR meter in a larger grow room, you already know the problem — reaching the centre of the canopy cleanly, holding the sensor at exactly canopy height, and doing it without stepping over plants or disturbing anything. The Treegers PAR Meter Extendable Wand solves that. It telescopes from 25cm to 75.5cm, threads onto the sensor's standard 1/4" screw mount, and lets you position the sensor precisely where you need it without reaching in yourself. Small product, specific job, does it well.

Telescopes 25cm to 75.5cm Collapses to a compact 25cm for storage and extends to 75.5cm — enough reach to span most tent footprints from the edge without stepping inside.
Standard 1/4" Screw Mount Threads directly onto the Treegers PAR Meter sensor unit's 1/4" socket — the same fitting used on tripods and camera accessories. No adapter needed.
Metal Construction Aluminium alloy body. Holds the sensor position without flexing under its own weight, which matters when you need readings from a fixed height.
Consistent Canopy-Level Readings Holding the sensor at a consistent height manually is harder than it sounds. A rigid wand eliminates hand wobble and angle variation across multiple measurement points.
Lightweight at 100g The wand adds just 100g to the sensor unit — light enough to handle single-handed while reading the display in your other hand.
Works With Any 1/4" Compatible Meter While designed for the Treegers PAR Meter sensor, the 1/4" thread means it will work with any PAR or quantum sensor that uses the standard 1/4" screw mount.

Tech Specs

Colour: Black
Material: Metal
Collapsed Length: 25cm
Extended Length: 75.5cm
Mount Type: 1/4" inch screw (gimbal)
Weight: 100g
Compatibility: Treegers Quantum PAR Meter sensor unit; any sensor with 1/4" screw mount

What's in the Box

1x PAR Meter Extendable Wand Black metal telescoping wand with 1/4" gimbal screw mount. Ready to attach to the Treegers PAR Meter sensor straight out of the box.
How to Get More Out of Your Canopy Map
  • The wand is most useful in rooms and tents wider than 1.2m where reaching the centre cleanly from the edge is otherwise awkward without disturbing the canopy.
  • Extend the wand to canopy height, lower the sensor to the leaf level at each measurement point, and save the reading before moving to the next position. Consistent height matters more than speed.
  • Take readings at a minimum of five points — four corners and centre. For rooms larger than 1.5m x 1.5m, a 9-point grid (3x3) gives a much more accurate uniformity picture.
  • The gimbal at the top of the wand allows the sensor to be angled — always keep the sensor face pointing directly upward (perpendicular to the canopy) for accurate PPFD readings. Angled sensors read lower values than they should.
  • Use the saved readings in the Treegers PAR Meter's AVG function to calculate your average canopy PPFD for use with the Growcast's PPFD targeting feature.

How to Use the Extendable Wand

1
Thread the sensor onto the wand's 1/4" mount — The Treegers PAR Meter sensor unit has a 1/4" screw socket on the base. Thread it clockwise onto the wand's gimbal mount until finger-tight. The gimbal joint allows you to set the sensor angle — lock it so the sensor face is perpendicular to the ceiling.
2
Connect the sensor cable to the PAR meter main unit — Attach the coiled or straight cable between the sensor and the main display unit before extending the wand. Hold the main unit in your non-dominant hand — the wand extends away from you into the canopy while you read the display comfortably.
3
Extend the wand to your target measurement height — Slide the inner section of the wand to the length that positions the sensor at canopy level for your setup. The wand locks in place at the extended length — confirm it is secure before positioning over the canopy.
4
Position the sensor at each measurement point and save — Hold the wand steady over each grid point, wait for the reading to stabilise on the display, and press save. Work systematically across your measurement grid — corners first, then midpoints, then centre — so you don't lose track of positions.
5
Review AVG, Min, and Max on the PAR meter — Once all readings are saved, use the PAR meter's Max/Min/AVG function to assess your canopy uniformity. A tight spread between Min and Max indicates good uniformity from your fixture. A wide spread tells you where to adjust fixture height or position.

Pairs Well With

Treegers Quantum PAR Meter

The wand mounts directly to the PAR Meter sensor unit's 1/4" socket. These two products are designed to be used together.

Treegers Growcast Controller

Canopy PPFD data from your wand-assisted measurements feeds directly into the Growcast's PPFD targeting feature.

Treegers GL420W LED Fixture

Use the wand to map PPFD uniformity across the GL420W's 1.2m canopy footprint. Confirms your fixture height and dimmer setting are dialled in correctly.

Treegers GL650W+ LED Fixture

At 1.5m canopy coverage, the wand becomes more useful — reaching the centre from the edge of a 1.5m room requires the extended length.

Treegers GL1000W+ LED Fixture

Mapping a 1.5 x 1.8m canopy cleanly by hand is awkward. The extended wand makes a thorough 9-point grid measurement practical.

LED Grow Lights

The wand works with any PAR meter using a 1/4" sensor mount — useful for verifying the output of any grow light in your room, not just Treegers fixtures.

Frequently Asked Questions

Will this wand work with my Treegers Quantum PAR Meter?

Yes — the wand is designed specifically for the Treegers Quantum PAR Meter. The sensor unit on that meter includes a 1/4" screw socket that accepts the wand's gimbal mount directly. No adapters or tools required.

Will it work with other brands of PAR meter?

Yes, potentially — the 1/4" gimbal mount is a standard thread size used on many sensor accessories. If your PAR meter sensor has a 1/4" socket, the wand will attach. Check your sensor's base for a 1/4" thread before ordering.

How long is it when fully extended?

The wand extends to 75.5cm from a collapsed length of 25cm. Combined with your arm reach from the edge of a tent, 75.5cm is enough to reach the centre of most standard 1.2m and 1.5m tents without stepping inside the canopy.

Do I need this wand if my tent is only 1.0 x 1.0m?

Not really — in a 1.0 x 1.0m tent you can reach the centre manually with the standard 1.5m coiled cable on the PAR meter. The wand becomes genuinely useful in 1.2m tents and larger, where getting the sensor accurately into the centre without stepping over plants and disturbing the space becomes awkward without one.

Does the sensor need to be perfectly level to get accurate readings?

Yes — the sensor face should be pointing directly upward, perpendicular to the ceiling and the light source above it. Angling the sensor even a few degrees reduces the measured PPFD value because you are capturing a smaller effective area of the light cone. The wand's gimbal allows you to set and lock the sensor angle before positioning it over the canopy — use this to confirm the sensor is flat and upward-facing before each reading.

Reach Every Corner. Read Every Point.

A PAR map is only as accurate as the positions you can actually reach. The wand makes the full canopy accessible without disturbing it. Questions about PAR mapping your grow room? The Grow Guys team knows the numbers.

Shop All Treegers

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.


Recently viewed